Investigating Hydrogen Peroxide Decomposition: Calorimetry Analysis

Categories: CompositionHydrogen

Abstract

The primary objective of this research is to thoroughly explore and understand the method for determining the heat of decomposition of hydrogen peroxide through calorimetry. The experiment involves utilizing a low-cost calorimeter, a Styrofoam cup, to examine the enthalpy changes during the decomposition process, with a careful consideration of the heat absorbed by the calorimeter. The resulting enthalpy of decomposition, measured at -57.9 kJ/mol, will be critically analyzed in comparison to the literature value of -94.6 kJ/mol. This essay delves into the experimental procedure, discusses potential sources of error, proposes enhancements for future investigations, and provides an in-depth exploration of the scientific principles underlying the experiment.

Introduction

Calorimeter Overview

Calorimetry is a pivotal branch of thermodynamics, focusing on the measurement of heat exchanged during chemical reactions. In our investigation, we opted for a simple yet effective calorimeter—a Styrofoam cup. The choice of this calorimeter is motivated by its affordability and insulating properties. The Styrofoam cup ensures minimal heat exchange with the surroundings, making it an ideal candidate for experiments where precise heat measurements are crucial.

Get quality help now
RhizMan
RhizMan
checked Verified writer

Proficient in: Composition

star star star star 4.9 (247)

“ Rhizman is absolutely amazing at what he does . I highly recommend him if you need an assignment done ”

avatar avatar avatar
+84 relevant experts are online
Hire writer

However, the simplicity of the calorimeter comes with its own set of challenges. As heat is generated or absorbed during a chemical reaction, the calorimeter itself absorbs a portion of this heat. To obtain accurate results, it becomes imperative to account for the heat absorbed by the calorimeter in the overall energy balance of the reaction.

To minimize heat loss during the experiment, the reactants are sealed inside the calorimeter with a lid.

Get to Know The Price Estimate For Your Paper
Topic
Number of pages
Email Invalid email

By clicking “Check Writers’ Offers”, you agree to our terms of service and privacy policy. We’ll occasionally send you promo and account related email

"You must agree to out terms of services and privacy policy"
Write my paper

You won’t be charged yet!

This not only prevents heat from escaping but also ensures that the experimental conditions remain consistent throughout the duration of the reaction. Additionally, a thermometer is strategically placed inside the calorimeter to monitor and record temperature changes—a crucial parameter for analyzing the heat of decomposition.

Understanding Heat of Decomposition

The experiment focuses on hydrogen peroxide (H2O2), a compound with inherent instability. Under normal room conditions, hydrogen peroxide slowly decomposes into water and oxygen. However, this decomposition process is considerably slow and may not be completed within a typical laboratory period.

To expedite the decomposition process, a catalyst is introduced. In this case, Iron (III) nitrate serves as a catalyst, accelerating the breakdown of hydrogen peroxide without being consumed in the reaction. This catalyzed decomposition provides a controlled environment for studying the heat of decomposition.

Procedure

Part 1: Determining Calorimeter Heat Capacity

The experiment unfolds in two intricate parts, each designed to contribute to a comprehensive understanding of the heat of decomposition. In the initial part, the focus is on determining the heat capacity of the calorimeter. This involves a meticulous procedure to ensure accurate measurements.

Firstly, 30ml of tap water is carefully poured into the Styrofoam cup calorimeter. The system is then allowed to equilibrate at room temperature for 5-10 minutes before recording the initial temperature. Subsequently, an additional 30ml of water, preheated to approximately 20°C above room temperature, is introduced into the calorimeter. The temperature is observed and recorded over a three-minute period, capturing the dynamic changes in the system.

Part 2: Enthalpy of Hydrogen Peroxide Decomposition

Following the meticulous completion of the first part, the experiment progresses to the main investigation—the determination of the enthalpy of hydrogen peroxide decomposition. This stage involves a series of carefully orchestrated steps to ensure precision in measurements and data recording.

The calorimeter and thermometer, having been thoroughly dried, are prepared for the introduction of hydrogen peroxide. 50ml of 1.0M hydrogen peroxide is cautiously measured and added to the calorimeter. The system is sealed with the lid, and the thermometer is positioned to monitor temperature changes throughout the reaction.

The experiment introduces a dynamic element by adding 10ml of 0.50M Iron (III) nitrate [Fe(NO3)3], serving as the catalyst. Temperature measurements are continued for a total duration of 20 minutes, capturing the entire course of the reaction. A temperature vs. time curve is then constructed using the data obtained, allowing for a detailed analysis of the temperature changes during the reaction.

The enthalpy of decomposition is calculated by extrapolating temperatures before and after adding the catalyst to determine the initial and final temperatures for the reaction. The resulting enthalpy value obtained from this process is -57.9 kJ/mol.

Discussion

The discussion section is critical for interpreting the results obtained and identifying potential sources of error that may have influenced the outcome of the experiment.

The derived enthalpy of decomposition, -57.9 kJ/mol, presents a notable deviation from the literature value of -94.6 kJ/mol. This variance prompts a thorough examination of the experimental setup and procedure to understand the factors contributing to this difference.

One significant source of error is the imperfect nature of the calorimeter. The Styrofoam cup's lid does not provide complete coverage, allowing heat to escape and compromising the accuracy of the results. Additionally, the extended 20-minute duration of the experiment contributes to heat loss from the calorimeter over time, resulting in lower-than-expected temperature differences and, consequently, a lower enthalpy value.

Another potential point of heat loss occurred during the addition of Iron (III) nitrate as a catalyst. The slow closure of the calorimeter's lid during this phase allowed a significant amount of heat to be lost to the surroundings. Additionally, the imprecise calibration of the thermometer, rounded to the nearest 0.5°C, introduces further inaccuracies into the results.

To enhance the experimental setup and mitigate potential sources of error, the utilization of an adiabatic calorimeter is recommended. This advanced calorimeter, surrounded by a jacket containing water, minimizes heat exchange with the surroundings, providing more accurate results. Reducing the experiment duration to 15 minutes can also mitigate heat loss, and using a finely calibrated thermometer will enhance temperature measurement precision.

Furthermore, consideration can be given to the choice of catalyst and its introduction method to minimize heat loss during this critical phase of the reaction. A meticulous approach to sealing the calorimeter and ensuring swift closure of the lid can further contribute to more accurate temperature measurements.

In conclusion, the discussion serves not only to identify sources of error but also to propose practical solutions and improvements for future investigations. The rigorous analysis of the experimental setup and its potential limitations lays the groundwork for refining the methodology and obtaining more accurate results in subsequent studies.

Conclusion

The conclusion section offers a comprehensive summary of the experiment's findings, emphasizing the significance of the results in the broader context of chemical kinetics and thermodynamics.

In conclusion, the experiment provides valuable insights into the intricacies of hydrogen peroxide decomposition and the challenges associated with accurately measuring the heat of this reaction. The results obtained, while deviating from the literature value, underscore the importance of a meticulous experimental setup in achieving reliable and precise measurements.

The limitations of the simple Styrofoam cup calorimeter are evident in the context of this experiment. The incomplete coverage of the lid and the extended duration contribute to heat loss, impacting the accuracy of the enthalpy value obtained. The recommendations for an adiabatic calorimeter, reduced experiment duration, and a finely calibrated thermometer emerge as crucial enhancements for future investigations.

Ultimately, the experiment contributes not only to the understanding of hydrogen peroxide decomposition but also to the broader scientific endeavor of refining experimental methodologies for accurate and reproducible results. It highlights the dynamic interplay between experimental design, instrumentation, and the inherent complexities of chemical reactions—a dynamic that requires careful consideration and continuous improvement for advancements in scientific knowledge.

Updated: Dec 15, 2023
Cite this page

Investigating Hydrogen Peroxide Decomposition: Calorimetry Analysis. (2016, Nov 19). Retrieved from https://studymoose.com/heat-of-decomposition-of-hydrogen-peroxide-essay

Investigating Hydrogen Peroxide Decomposition: Calorimetry Analysis essay